Friday 9 August 2024

How to Keep The Stability Chamber In Top Shape With General and Preventive Maintenance?

Is the stability chamber in your laboratory rendering peak performance?  If your answer is no, running preventive and general maintenance may serve the purpose.  Not conducting maintenance checks may mean that you will find yourself repairing the damages or the worst case scenario is buying a new instrument.

You may have some very pertinent questions about the preventive maintenance techniques of the stability chamber. Here is what you need to know about maintaining the cleanliness of this equipment:

·         Conduct regular inspection of the device

During the preventive maintenance check of the stability chamber, you need to examine its key components and document the record of inspection. However, before you run the check, be sure to prepare a checklist and adhere to it when doing the work. That way, you can gauge how well or bad is the functioning of the device and the remedial stapes need to be taken.

·         Caring for the condenser and compressor

Maintaining the condenser and compressor is essential to determine whether the device is performing optimally or if there are any anomalies. If issues are detected during the process, you need to run maintenance checks more often so that right measures can be taken for seamless operation.

·         Preparing for emergencies

During the creation of a maintenance plan, you need to have a plan ready for equipment failure. Most importantly, you need to have an appropriate backup procedure in place to handle the emergencies.

Maintaining the humidification experience

For preventive maintenance of the humidification system of the stability chamber, there are three major components to consider:

·         Humidity system fan

You must replace the fan of the system when it completes about 55,000 hours of continued usage.

·         Filter

The filter of the stability chamber must be changed within every six months as it is a mixed bed filter. However, when the equipment runs more frequently, the duration of replacement will shorten and become four months.

·         Humidifier nebulising unit

The humidifier nebulising unit is a sensitive component and must be replaced within just 10,000 hours of continued usage.

General maintenance tips for stability chambers

Are you preparing to run a maintenance check on the stability chamber?  Here is how to make the process seamless:

v  During the maintenance check, you need to position the device on a strong base to ensure that the entire process runs with ease and fewer disruptions.

v  Don’t insert any inflammable substance inside the chamber when performing the checks.

v  Try to keep the space around the chamber clear

v  If anything happens inside the stability chamber and prevents it from running the maintenance check, you need to check if something is wrong. It may also indicate that it’s time to replace the chamber.

Once you prepare the chamber for running maintenance checks, here are the general maintenance tips to follow:

·         Checking the filter

Based on the types of filters used inside the stability chamber, you must schedule replacement or clean them for optimal performance.

·         Insulation and door seals

Does the door seal of the chamber function correctly? Find out how much is the degree of wear and tear on the machine. If the seals are not damaged and the insulation seems perfect, you need not worry about replacing these parts of the chamber.

·         Cleaning the equipment properly

When it comes to cleaning of these chambers, you need to perform the procedure properly. However, you need to follow the cleaning instructions properly and adhere to the recommended cleaning agents.

·         Check the calibration

Checking the status of calibration is one of the essential maintenance tips to follow. In case, the readings do not come accurate, you need to call an expert for better outcome.

So, here is all you wanted to know about maintaining stability chambers ad ensuring optimal performance of this device. One of the major dilemmas that laboratory workers face is whether to conduct DIY maintenance or call an expert?  Now, it all depends on the complications that occur during the maintenance check. Overall, calling an expert for help may be essential when you also need to troubleshoot common issues within the device.

Are you yet to buy the stability chamber and looking for a reliable manufacturer? Trust I Gene Labserve for buying industrial-grade and laboratory equipment. Click here https://www.igenels.com/ to explore the prices.

Why Is a Centrifugal Vacuum Concentrator a Versatile Tool For Laboratory Research?

  Centrifugal vacuum concentrators combine heat, vacuum, and centrifugal force to evaporate several small samples quickly and gently into ...